AUTOOL CT60 · Dual-Output Injector Signal Generator
Drive Two Injectors for Controlled Response Checks
Drive two compatible injectors together with this handheld pulse tester, using a separate approved cleaning or observation setup to compare response and spray behavior. Select standard 12 V or instantaneous 75 V output to match the injector requirement, then adjust simulated speed from 600–4,000 RPM and output time from 0–99 minutes. The LCD and pulse indicator keep settings and activation visible.
- Dual-Injector Pulse Output
- 12 V / Instantaneous 75 V
- 600–4,000 RPM Settings
- 0–99 Minute Output Timer
- Separate Ultrasonic-Tank Companion

Key Features
Standard and High-Voltage Modes with Dual Outputs
Standard Injector Mode
Use the 12 V output for compatible standard electromagnetic gasoline injectors after confirming the injector requirement.
Compatible High-Voltage Mode
An instantaneous 75 V output helps drive the electromagnetic valve in compatible high-voltage injectors. For a turbocharged application, use this mode only when the injector is confirmed as a compatible high-voltage type.
Wide RPM Adjustment
Set 600–4,000 RPM to compare injector response and spray behavior under controlled simulated speeds.
Adjustable Working Time
Set output duration from 0 to 99 minutes for controlled injector activation during the cleaning, observation, or comparison procedure.
LCD Digital Settings
Read working frequency and time on the LCD so you can record and repeat the same injector-drive settings.
Dual-Injector Output
Drive two compatible injectors together to compare response, spray shape and spray angle under one approved external fluid and observation setup.
Pulse Output Indicator
A working indicator shows when CT60 is sending the injector pulse signal.
Ultrasonic-Cleaning Companion
Use the CT60 to pulse compatible injectors during cleaning with a separate ultrasonic cleaning tank.
Compact Handheld Control
Keep the LCD, setting controls and injector connections close to the work area with the compact 138 × 76 × 30 mm handheld body.
3 Years Warranty Support
Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.
Safety & Compatibility
Confirm Injector Type, Wiring, Voltage Mode, and Duty Cycle
Use It As A Signal Generator
CT60 needs separate equipment to hold the injector and safely manage cleaning or test fluid.
Confirm Drive Compatibility
Match the drive voltage to the injector specification. Confirm the requirement before selecting 75 V.
Control Fuel And Cleaner
Work with ventilation, eye protection and a contained spray path; keep fuel and cleaner away from flames, sparks and hot parts.
Use The Supplied Power Hardware
Follow the manual for the power adapter and cables. Never connect clamp leads directly to 110/220 V AC mains.
Stop On Abnormal Heat Or Damage
Stop immediately if a cable, adapter, connector or injector becomes loose, damaged, hot or abnormal.
Check The Complete Setup
Before buying, confirm injector connector, drive requirement, separate cleaning/test equipment and fluid method.
Compare Injector Response
Use the visible response and spray pattern for matched comparison; use calibrated flow equipment when the job requires measured delivery or OEM limits.
Avoid High-Voltage Parts
Do not touch vehicle parts marked with a dangerous voltage logo.
Use Supplied Electrical Equipment
Use the supplied power adapter and cables only according to the CT60 user manual and local electrical safety rules.
Test Results
Observe Response Without Claiming Flow Performance
Confirm Actuation First
The pulse indicator plus an audible or visible injector response shows that the control signal reached the setup; no response still requires connector, power and injector checks.
Compare Like With Like
Compare injectors of the same application at the same mode, RPM, time, fluid and fixture position. A repeatable difference is more useful than one isolated observation.
Read the Fuel Injector Spray Pattern
Compare pattern and angle between matched injectors under the same settings, then repeat any irregular response before the next diagnostic step.
Watch For Dripping
Unwanted drops or continued wetting during the approved observation procedure can justify a repeat test and further sealing diagnosis.
Retest After Cleaning
Repeat the original settings after cleaning. Improvement, no change and intermittent behavior are all useful outcomes to record.
Choose the Next Injector Test
CT60 provides pulse control and visual spray comparison. Use calibrated flow or high-pressure equipment for measured delivery, GDI validation or unresolved vehicle faults.
Specifications
CT60 Specifications
| Workflow Scope | |
|---|---|
| Primary task | Injector pulse generation and visual response support |
| Fluid system | Requires separate suitable equipment |
| Simultaneous positions | 2 injector outputs |
| Allowed conclusion | Visible actuation/spray difference |
Manual & Downloads
Use the Manual for Setup and Test Modes
AUTOOL CT60 Manual & Guides
Visit the manual download center to find model-specific CT60 setup, injector-mode selection, RPM and timing controls, electrical safety, and troubleshooting guidance.

Package
What’s Included
- CT60 Main UnitFuel injector signal generator with LCD controls.
- Signal CableInjector pulse-signal connection cable.
- Clamp CablePositive and negative clamp cable for the power connection.
- Power AdapterPower adapter for the CT60 setup.
- Connector AccessoriesInjector cleaning and test connector accessories.
- Documentation And BoxUser manual and CT60 retail box.
FAQs
Injector Drive and Connection Questions
Is CT60 a complete injector cleaner and tester?
No. It generates injector pulse signals and must be paired with suitable equipment that handles cleaning fluid or spray observation.
Which injectors can CT60 drive?
It provides a 12 V standard mode and an instantaneous 75 V mode for compatible high-voltage injectors. Confirm the exact injector requirement before use.
Can it compare two injectors?
Yes. Two compatible injectors can be driven together under the same setup for a visual response and spray comparison.
Does it measure injector flow?
No. CT60 supports visual response and spray-pattern comparison. Choose a calibrated injector bench when measured flow is required.
What can I adjust?
The LCD controls 600–4,000 RPM and 0–99 minutes, along with the injector drive mode.
Can CT60 pulse injectors during ultrasonic injector cleaning?
Yes, with a separate suitable ultrasonic setup, compatible connector and approved cleaning method.
How do I power it safely?
Use the supplied adapter and correct cables according to the manual. Never connect clamp leads directly to AC mains.
What does an uneven spray prove?
Repeat the observation under the same settings. If the difference remains, continue with calibrated flow, electrical or on-vehicle testing as the job requires.
What is the warranty?
Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.
How Do I Observe The Injector Spray Pattern?
Prepare and connect the injector safely, select its verified drive mode, set RPM and working time, and use suitable cleaning or test equipment to observe response, spray pattern, and spray angle.
What Safety Precautions Should I Follow?
Turn off the engine, keep fuel away from heat and flame, ventilate the work area, avoid rotating, hot, and high-voltage parts, and wear qualified safety goggles.
What Is Included In The CT60 Package?
Package contents: CT60 main unit, signal cable, clamp cable, power adapter, connector accessories, user manual, and retail box. Check the contents of the selected package before ordering.