AUTOOL HTS828 · Dual-Gauge 7.5 kg Automotive Dry Ice Blaster
Compare Inlet and Blasting Pressure While Cleaning
Read inlet supply and outlet working pressure separately while adjusting dry ice delivery from 0 to 3.2 kg/min for the tested surface. The 7.5 kg hopper uses 3 mm pellets, and a large oil-water separator with spiral feed helps reduce clumping and line blockage. A mobile metal body, gun holder and accessible controls support workshop cleaning with a suitable external dry-air compressor.
- Dual Pressure Gauges
- 0–3.2 kg/min Adjustable Feed
- 7.5 kg Dry Ice Hopper
- Oil-Water Separator
- Spiral Feed Control

Key Features
Dual Pressure Gauges and Adjustable Ice Delivery
Dual Pressure Monitoring
View inlet supply and outlet working pressure separately while checking blasting stability.
External Air Requirement
Supply more than 1–2 m³/min of dry compressed air at working pressure; the external compressor is not included.
Moisture and Clumping Control
A large oil-water separator and spiral feed help reduce wet-air clumping and line blockage.
Adjustable Dry Ice Feed
Adjust delivery from 0 to 3.2 kg/min, increasing gradually to establish a tested setting for the target surface and cleaning task.
Mobile Safety Layout
Metal housing, emergency stop, gun holder, handle and casters support workshop operation.
No Solid Dry-Ice Media Residue
Pellets sublimate; removed carbon, oil and debris must still be managed.
3 Years Warranty Support
Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.
Safety & Compatibility
Verify Ventilation, Air Quality, and Surface Suitability
Air Supply
Compressor not included; verify >1–2 m³/min at working pressure, dry air, hose/fitting capacity and duty cycle.
Dual Gauges Are Monitoring Tools
They do not replace surface tests, the vehicle procedure or operator control.
CO₂/Cold/Noise
Ventilate and use gloves, goggles, hearing protection, protective clothing and closed-toe shoes.
Sensitive Areas
Test a small area first and use suitable settings around sensors, coatings, plastics, rubber, and aged surfaces.
Power and Debris
Confirm grounded regional voltage and plan collection of removed contamination.
Specifications
HTS828 Specifications
| Operating specifications | |
|---|---|
| Working Principle | Dry Ice Flushing |
| Input Voltage | 110/220V |
| Dry Ice Capacity | 7.5 kg |
| Airflow | >1–2 m³/min |
| Dry Ice Injection Quantity | 0–3.2 kg/min |
| Air Source Pressure | 0.3–1.0 MPa |
| Compatible Nozzles | 5 Types |
| Rated Power | Not stated |
| Media, consumption, and mass | |
| Dry Ice Particles | 3 × 6 mm |
| Flushing Consumption | 3-5KG |
| Net Weight | Not stated |
| Gross Weight | Not stated |
| Hardware and applications | |
| Pressure Gauge | Dual |
| Handle | ✓ |
| Built-in Filter | ✓ |
| Ice Output Knob | ✓ |
| 360° Casters | ✓ |
| Applicable Vehicle Models | Fuel Vehicles, Hybrid Vehicles, Electric Vehicles |
Manual & Downloads
HTS828 Manual & Setup Help
AUTOOL HTS828 User Manual
Open the PDF manual for HTS828 dry ice loading, inlet and outlet pressure monitoring, moisture separation, feed adjustment, surface safety, and troubleshooting.

Package
What’s Included
- HTS828 Main Unit7.5 kg dual-gauge dry ice blaster.
- Multiple Nozzle AccessoriesMultiple spray nozzles are available; confirm the exact pieces and quantities in the current packing list.
- External SuppliesCompressor and dry ice are required separately.
- Packing List ConfirmationConfirm all hoses, cables, PPE and parts for the selected shipment.
FAQs
Air Supply and Pressure Questions
What air supply does HTS828 require?
Use 0.3–1.0 MPa and more than 1–2 m³/min; normal operation begins from 4 bar. Confirm actual dynamic compressor output.
What do the dual gauges show?
They display inlet air pressure and outlet working pressure separately.
What dry ice pellets does HTS828 use?
3 mm pellets in a 7.5 kg hopper.
Does it eliminate all cleanup?
No solid dry-ice media remains, but removed contamination still needs collection and CO₂ requires ventilation.
Is it safe for every sensor or coating?
No. Use tested conservative settings and confirm material/coating suitability.
How does it differ from HTS818?
HTS828 adds dual pressure gauges and uses more than 1–2 m³/min; HTS818 uses more than 1–3 m³/min with a single gauge.




