AUTOOL SDT100 · Portable Smoke Leak Detector with Built-In Pump
Trace Visible Low-Pressure Leaks Without Shop Air
This automotive smoke leak detector uses its built-in pump to generate smoke and trace visible leak paths without a separate shop-air source. SDT100 supports low-pressure EVAP, vacuum, intake, exhaust, crankcase, sealing, fuel-tank, coolant-tank, and turbo-path checks, with smoke available in about five seconds after the unit is activated.
- Built-In Pump, No Shop Air
- About 5-Second Smoke Start
- Permitted Low-Pressure Systems
- 12 V Vehicle-Battery Power
- Operation Down To -20°C

Key Features
Built-In Air Supply in a Portable Smoke Tester
EVAP and Vacuum Leak Detection
SDT100 can be used as a diagnostic tool for vacuum systems to detect vacuum leaks. It also supports leak checks for EVAP systems, intake systems, exhaust systems, crankcases, oil seals, intercooler air paths, fuel tanks, coolant tanks, line fittings, and low-pressure turbo systems.
Built-In Air Pump
No extra pump is required. The built-in air pump helps save setup time and makes smoke leak detection easier for both technicians and automotive enthusiasts.
Overheat + Low-Temperature Protection
Overheat and freeze protection automatically stop operation when needed. The unit can operate at temperatures down to -20°C.
Grouped Controls & Connections
The smoke switch, power and alarm indicators, oil filler, smoke output, power socket, and handle are grouped in one compact layout. This makes setup and component identification easier.
3 Years Warranty Support
Main unit: 3-year warranty. Standard accessories: 1-year warranty.Warranty Policy.
Safety & Compatibility
Use the Vehicle Procedure and a Safe Test Pressure
12V Power and Built-In Air Pump
Connect SDT100 to a 12V DC battery before use. The built-in air pump provides the test airflow, so you do not need an external compressor.
Testing Oil Is Not Included
Testing oil is not included. Use liquid paraffin or baby oil and add 10–15 mL before use.
Limit Continuous Use to 8 Minutes
Do not run SDT100 continuously for more than 8 minutes. Automatic overheat protection shuts the unit off above 75°C. Let it cool before restarting.
Operating Temperature and Hot Surfaces
SDT100 supports operation down to -20°C. The round metal housing can become hot during use, so avoid touching hot surfaces directly.
Do Not Use for Direct High-Pressure A/C Testing
SDT100 cannot directly pressure-test an automotive A/C system. If a service procedure permits smoke on an isolated A/C line section, follow that procedure and use smoke only as an indirect visual aid.
Trace the Leak with Smoke
Use visible smoke to trace the leak area. If no smoke appears, recheck isolation, flow, and the test setup before continuing.
Never Refill While Running
Do not refill testing oil while SDT100 is running.
Indicator Shows Unit Status
Use the fault indicator for unit status, not as a pressure or airflow reading.
Cool Before Restarting
Let the unit cool before restarting after overheat protection is triggered.
Avoid Hot Metal Housing
Avoid touching the metal housing when it is hot.
Specifications
SDT100 Specifications
| Smoke Output & Protection | |
|---|---|
| Working Principle | Low Oxygen Combustion |
| Test Oil Filling Volume | 10-15ml |
| Rated Output Pressure | <10 psi machine-rated output; use the target-system procedure. |
| Rated Output Flow | <5L/min |
| High-Temperature Protection | Stops working above 75°C |
| Response Time | Produces smoke in 5 seconds |
| Power & Physical Size | |
| Input Power | DC12V |
| Rated Power | 50W |
| Net Weight (Main Unit) | 1.6kg |
| Main Unit Dimensions | 180mm*102mm*143mm |
| Monitoring & Controls | |
| Air Source Type | Built-in Air Pump |
| Mode Output | Smoke Mode |
| Fault Indicator Light | Yes |
Manual & Downloads
Use the Manual for Setup and Test Pressure

AUTOOL SDT100 User Manual
Open the PDF manual for SDT100 smoke generation, built-in pump operation, permitted low-pressure leak tests, test-oil handling, safety, maintenance, and troubleshooting.

Package
What’s Included
- Main UnitAUTOOL SDT100 smoke leak detector
- Power Cable12V battery clamp cable
- Smoke HoseSmoke output hose
- AdaptersCone adapter, red connector, thin hose, and airbag adapter
- Oil BottleEmpty testing oil bottle included; testing oil is not included
- DocumentationUser manual and SDT100 retail box
FAQs
Pump, Smoke Fluid, and Connection Questions
What Testing Oil Should I Use for SDT100?
Testing oil is not included. If dedicated smoke-testing oil is unavailable, use liquid paraffin or baby oil.
How Much Testing Oil Should I Add?
Add 10–15 mL testing oil before use. Do not add more than 15 mL at a time. Refill only when the smoke becomes thin, and drain remaining testing oil before adding fresh testing oil. If too much oil is added accidentally, drain some oil out before operation.
Can I Use SDT100 as an EVAP Smoke Machine?
Yes. AUTOOL smoke leak detectors can test leaks in the EVAP system. Use the EVAP adapter or service tool that matches the vehicle test port.
Can SDT100 Directly Test Automotive A/C System Leaks?
No. The automotive A/C system operates at about 1.7–3.0 MPa output pressure, while SDT100 has rated output pressure below 10 psi. SDT100 cannot directly pressure-test the automotive A/C system for leaks. Use smoke only to help inspect an A/C line section after isolating and pressurizing it according to the service procedure.
How Can Smoke Help Locate a Leak in an Isolated A/C Line Section?
First isolate and pressurize the A/C line segment according to the vehicle or A/C service procedure. Then apply smoke near the test section and observe whether escaping airflow disturbs the smoke. If escaping air moves the smoke, inspect that area for a possible leak.
What Systems Can SDT100 Test?
SDT100 can locate vacuum leaks and also supports low-pressure checks across EVAP, intake, exhaust, crankcase, and low-pressure turbo systems. It can also check oil seals, intercooler air paths, fuel tanks, coolant tanks, line fittings, and engine sealing areas.
What Power Supply Does SDT100 Need?
SDT100 runs on a 12V DC vehicle battery. This makes it convenient for vehicle maintenance and easy to power in typical automotive repair environments.
Can I Adjust the Pressure on SDT100?
SDT100 uses fixed smoke-mode output below 10 psi. If separate Standard and EVAP pressure modes are required, compare SDT208. Use SDT100 only within its specified low-pressure range.
What Accessories Are Included?
Check the product listing or your selected package option for the exact items included. SDT100 includes the main unit, 12V battery clamp cable, smoke hose, cone adapter, red connector, thin hose, and airbag adapter. The package also includes an empty testing oil bottle, user manual, and retail box. Testing oil must be purchased separately.
How Do AUTOOL Smoke Leak Detector Models Differ?
- External-air EVAP: SDT101 and SDT103 — 3.2 kPa / 0.46 psi.
- Built-in pump: SDT106 <12 psi; SDT203/SDT205/SDT205S <15 psi; SDT206 dual pumps <18 psi.
- Dual pressure: SDT208 — 35 psi Standard / 10 psi EVAP.
Also compare flow, modes, and accessories before ordering.
How Long Is the Warranty?
Main unit: 3-year warranty. Standard accessories: 1-year warranty.Warranty Policy.




