Smoke Leak Detector

AUTOOL SDT206 Dual-Pump Automotive Smoke Machine

Model SDT206

  • Dual Built-In Air Pumps: Two built-in pumps run separate Air and Smoke modes without an external air source.
  • Pressure + Adjustable Flow: Monitor line pressure and airflow, then adjust flow for the connected test setup.
  • EVAP + Low-Pressure Systems: Trace leaks in permitted EVAP, fuel-tank, intake, exhaust, crankcase, sealing, line-fitting, and low-pressure turbo checks.
  • Visible Oil Level + Drain: View testing-oil volume on the gauge and drain excess oil through the outlet.
  • Handle + Hook Body: Carry, hang, connect, and store the compact unit with its handle, hook, cone adapter, and airbag adapter.

SDT206

Manuals & Downloads

PDF

Smoke Leak Detector

AUTOOL SDT206

Language
English / German / Spanish / French
Updated
Download 9.3 MB

AUTOOL SDT206 · Dual-Pump Automotive Smoke Leak Detector with Flow Control

Monitor Pressure and Control Flow with Separate Built-In Pumps

Use separate built-in pumps for Air and Smoke modes without an external air source. Watch line pressure and airflow, adjust delivery for the connected permitted low-pressure test, then use smoke to trace the visible path; the oil-level gauge and drain outlet simplify testing-oil checks and excess-oil removal.

  • Separate Air And Smoke Pumps
  • Pressure And Flow Feedback
  • Adjustable Test Delivery
  • Oil-Level Gauge And Drain
  • About 5-Second Smoke Start
AUTOOL SDT206 smoke leak detector

Key Features

Dual Built-In Pumps with Pressure and Flow Monitoring

Air Mode and Smoke Mode

Independent switches let you use Air Mode for pressure and airflow checks, then switch to Smoke Mode for visual leak location.

Dual Built-In Air Pumps

Two built-in air pumps eliminate the need for an external air source during normal smoke leak testing.

Pressure Gauge Monitoring

Use the pressure gauge to observe line pressure. If pressure keeps dropping, the line may have a leak that requires further inspection.

Airflow Meter

The airflow meter lets you monitor airflow through the connected test line.

Flow Control Valve

Use the flow control valve to adjust airflow for the connected test line and test setup.

Smoke Starts in About 5 Seconds

The unit starts producing smoke quickly. The connected test line can fill in about 30 seconds, depending on system volume.

EVAP and Fuel-Tank Checks

Use the EVAP tool or adapter that matches the vehicle test port, then check the EVAP or fuel-tank system for leaks.

Intake and Exhaust Checks

Use it for low-pressure intake and exhaust leak checks when the test section is sealed and connected with an adapter that matches the opening.

Crankcase and Vehicle-Sealing Checks

Helps locate smoke escape points in crankcase and vehicle sealing checks; do not smoke-test any component that the vehicle or component service procedure excludes.

Low-Pressure Turbo Checks

Can assist with low-pressure turbo system leak checks. Do not use it as a high-pressure boost system tester beyond its rated pressure.

Line-Fitting Adapter Support

The smoke hose, adapters, rubber kits, and airbag adapter help connect the unit to different line openings and fittings.

Visible Oil Level Gauge

The oil level gauge helps you observe the current oil volume.

Oil Outlet

The oil outlet lets you drain excess testing oil when needed.

Handle + Hook Portable Design

The compact body, handle, hook, cone adapter, and airbag adapter make SDT206 easier to carry, position, connect, and store.

Overheat and Low-Temperature Protection

The unit turns off when the temperature exceeds 75°C and supports operation down to -20°C.

3 Years Warranty Support

Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.

Safety & Compatibility

Match Output to the Exact System and Procedure

12V Power and Dual Built-In Air Pumps

Connect SDT206 to a 12V DC vehicle battery before use. Two built-in air pumps provide the test airflow, so you do not need an external compressor.

Watch Pressure and Airflow Within Service Limits

SDT206 outputs less than 18 psi and less than 6 L/min. Use the pressure gauge, airflow meter, and flow control valve to watch and adjust the test within the vehicle or component service limits.

Use the Oil-Level Gauge, but Keep the 10–15 mL Fill Limit

Testing oil is not included. Use liquid paraffin or baby oil, add 10–15 mL before use, and use the oil-level gauge to check the current oil volume without overfilling.

Limit Continuous Use to 8 Minutes

Do not run SDT206 continuously for more than 8 minutes. Automatic overheat protection shuts off power above 75°C. Let the unit cool before restarting.

Operating Temperature and Hot Surfaces

SDT206 supports operation down to -20°C. The round metal housing can become hot during use, so avoid touching hot surfaces directly.

Use Only for Permitted Low-Pressure Automotive Tests

Use SDT206 for permitted low-pressure automotive leak checks, including low-pressure turbo paths within the stated limits. Do not use it for direct high-pressure A/C pressure testing or high-pressure boost-system testing.

Trace the Leak with Smoke

Use visible smoke to trace the leak area. If no smoke appears, recheck isolation, flow, and the test setup before continuing.

Never Refill While Running

Do not refill testing oil while SDT206 is running.

Check Procedure Before Smoke Testing

Follow the vehicle or component service procedure before introducing smoke into a system.

Keep Controls Within Pressure Range

Use the pressure and airflow controls within the permitted test-pressure range.

Cool Before Restarting

Let the unit cool before restarting after overheat protection is triggered.

Test Results

Read Pressure, Flow, and Smoke Separately

Use Pressure and Flow to Guide Inspection

Use the pressure gauge and airflow meter to assess line pressure and airflow, then guide the next leak-inspection step.

Visible Smoke Escape

Check that the outlet is not an intentional opening, then inspect, repair and retest the exact area.

No Visible Smoke

Verify access, isolation, valve state and smoke delivery before moving to functional diagnosis or another test method.

Specifications

SDT206 Specifications

Smoke Output & Protection
Working Principle Low Oxygen Combustion
Test Oil Filling Volume 10-15ml
Rated Output Pressure <18 psi machine-rated output; use the target-system procedure.
Rated Output Flow <6L/min
High-Temperature Protection Stops working above 75°C
Response Time Produces smoke in 5 seconds
Power & Physical Size
Input Power DC12V
Rated Power 70W
Net Weight (Main Unit) 3.5kg
Main Unit Dimensions 150mm*150mm*275mm
Monitoring & Controls
Flow Meter Window Yes
Pressure Gauge Yes
Air Source Type Built-in 2 Air Pump
Mode Output Air ModeSmoke Mode
Flow Adjustment Knob Yes
Oil Drain Valve Yes
Fault Indicator Light Yes
Oil Level Gauge Yes

Manual & Downloads

Use the Manual for Setup and Test Pressure

AUTOOL SDT206 user manual cover
Manual / PDF

AUTOOL SDT206 User Manual

Open the PDF manual for SDT206 dual-pump Air and Smoke modes, pressure and flow control, oil-level care, operating safety, and troubleshooting.

AUTOOL SDT206 package contents

Package

What’s Included

  • Main UnitAUTOOL SDT206 smoke leak detector
  • Power Cable12V battery clamp power cable
  • Smoke HoseSmoke output hose
  • AdaptersCone adapter, airbag adapter, and rubber adapter set
  • EVAP AccessoriesEVAP-related connectors, caps, and thin hose
  • Oil BottleEmpty testing oil bottle included; testing oil is not included
  • HookHanging hook
  • DocumentationUser manual and SDT206 retail box

FAQs

Pump, Flow, and System Questions

What Testing Oil Should I Use for SDT206?

Testing oil is not included. Use dedicated smoke-testing oil if available; otherwise use liquid paraffin or baby oil as specified for this model.

How Much Testing Oil Should I Add?

Add 10–15 mL testing oil before use. Do not add more than 15 mL at a time. Refill only when the smoke becomes thin, and drain remaining testing oil before adding fresh testing oil. If too much oil is added accidentally, drain some oil out before operation.

Can SDT206 Detect EVAP Leaks?

Yes. This EVAP smoke machine supports permitted low-pressure leak checks in the EVAP system. Use the EVAP adapter or service tool that matches the vehicle test port.

Can SDT206 Directly Test Automotive A/C System Leaks?

No. The automotive A/C system operates at about 1.7–3.0 MPa output pressure, while AUTOOL smoke leak detectors generate much lower pressure. SDT206 cannot directly pressure-test the automotive A/C system for leaks. Use smoke only to help inspect an A/C line section after isolating and pressurizing it according to the service procedure.

How Can Smoke Help Locate a Leak in an Isolated A/C Line Section?

First isolate and pressurize the A/C line segment according to the vehicle or A/C service procedure. Then apply smoke near the test section and observe whether escaping airflow disturbs the smoke. If escaping air moves the smoke, inspect that area for a possible leak. This method can help locate a leak in an isolated A/C line section, but it is not a direct high-pressure A/C test.

What Systems Can SDT206 Test?

SDT206 supports low-pressure leak checks for EVAP, intake, exhaust, crankcase, fuel-tank, vehicle-sealing, turbo, and line-fitting systems. Use an adapter that matches the test opening, and seal the test section before inspection.

What Power Supply Does SDT206 Need?

SDT206 runs on a 12V DC vehicle battery. Connect it to a 12V vehicle battery before operation.

Can I Adjust the Pressure on SDT206?

SDT206 uses fixed output below 18 psi. Its airflow meter and flow control valve monitor and adjust airflow; they do not change the pressure mode. If separate Standard and EVAP pressure modes are required, compare SDT208.

What Accessories Are Included with SDT206?

Check the product listing or your selected package option for the exact items included. The package includes the main unit, retail box, 12V power cable, smoke hose, cone adapter, hard rubber kits, airbag adapter, empty oil bottle, and hanging hook. EVAP-related accessories, red caps, the user manual, and other listed accessories are also included. Testing oil is not included.

How Do AUTOOL Smoke Leak Detector Models Differ?
  • SDT206: Two built-in pumps, separate Air/Smoke modes, pressure gauge, flow meter/control, oil drain, fault light, and oil-level gauge.
  • SDT208 alternative: 35 psi Standard / 10 psi EVAP.

The series also includes external-air EVAP, built-in-pump Smoke, Air/Smoke, and dual-pressure options; compare air source, pressure, flow, modes, and accessories.

How Long Is the Warranty for SDT206?

Main unit: 3-year warranty. Standard accessories: 1-year warranty. Warranty Policy.